{"id":757,"date":"2025-10-20T15:01:35","date_gmt":"2025-10-20T13:01:35","guid":{"rendered":"https:\/\/heyl.choyou-tools.fr\/?page_id=757"},"modified":"2025-10-20T15:02:39","modified_gmt":"2025-10-20T13:02:39","slug":"testomat-2000-clt-self-clean","status":"publish","type":"page","link":"https:\/\/heyl.choyou-tools.fr\/es_mx\/nos-produits\/testomat-2000-clt-self-clean\/","title":{"rendered":"Testomat 2000 CLT Self Clean"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"757\" class=\"elementor elementor-757\" data-elementor-settings=\"{&quot;ha_cmc_init_switcher&quot;:&quot;no&quot;}\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-198d0067 e-flex e-con-boxed e-con e-parent\" data-id=\"198d0067\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;shape_divider_bottom&quot;:&quot;waves&quot;,&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-shape elementor-shape-bottom\" aria-hidden=\"true\" data-negative=\"false\">\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 1000 100\" preserveaspectratio=\"none\">\n\t<path class=\"elementor-shape-fill\" d=\"M421.9,6.5c22.6-2.5,51.5,0.4,75.5,5.3c23.6,4.9,70.9,23.5,100.5,35.7c75.8,32.2,133.7,44.5,192.6,49.7\tc23.6,2.1,48.7,3.5,103.4-2.5c54.7-6,106.2-25.6,106.2-25.6V0H0v30.3c0,0,72,32.6,158.4,30.5c39.2-0.7,92.8-6.7,134-22.4\tc21.2-8.1,52.2-18.2,79.7-24.2C399.3,7.9,411.6,7.5,421.9,6.5z\"\/>\n<\/svg>\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-34d445da e-con-full e-flex e-con e-child\" data-id=\"34d445da\" data-element_type=\"container\" data-settings=\"{&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-423e elementor-widget elementor-widget-image\" data-id=\"423e\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"528\" height=\"750\" src=\"https:\/\/heyl.choyou-tools.fr\/wp-content\/uploads\/2025\/10\/Testomat-2000-THCL.png\" class=\"attachment-medium_large size-medium_large wp-image-688\" alt=\"\" srcset=\"https:\/\/heyl.choyou-tools.fr\/wp-content\/uploads\/2025\/10\/Testomat-2000-THCL.png 528w, https:\/\/heyl.choyou-tools.fr\/wp-content\/uploads\/2025\/10\/Testomat-2000-THCL-211x300.png 211w\" sizes=\"(max-width: 528px) 100vw, 528px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-20ee947a e-con-full e-flex e-con e-child\" data-id=\"20ee947a\" data-element_type=\"container\" data-settings=\"{&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3458513b elementor-widget elementor-widget-heading\" data-id=\"3458513b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testomat 2000\u00ae CLT Self Clean<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47156028 elementor-widget elementor-widget-text-editor\" data-id=\"47156028\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>The Testomat 2000\u00ae CLT Self Clean process photometer<br \/>with additional cleaning function for the measuring<br \/>chamber is an online analyzer for monitoring the content<br \/>of total chlorine (CLT) in the range of 0-2.5 mg\/l (ppm);<br \/>switchable to free chlorine in the same measuring range.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-35c452e9 e-flex e-con-boxed e-con e-parent\" data-id=\"35c452e9\" data-element_type=\"container\" data-settings=\"{&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-422b6cf e-con-full e-flex e-con e-child\" data-id=\"422b6cf\" data-element_type=\"container\" data-settings=\"{&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-43513114 elementor-widget elementor-widget-heading\" data-id=\"43513114\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Performance Profile<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2162f9af elementor-widget elementor-widget-text-editor\" data-id=\"2162f9af\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>\u2022 Analysis by automatic addition of 3 reagents<br \/>\u2022 Measurement result display after a reaction time<br \/>of approx. 1 minute (measurement time without<br \/>purging time)<br \/>\u2022 2 independently programmable limit contacts<br \/>for monitoring and control tasks<br \/>\u2022 Menu-guided operation and programming<br \/>by means of plain text display<br \/>\u2022 High measuring accuracy due to precise piston<br \/>metering pump<br \/>\u2022 Analysis triggers:<br \/>&#8211; Automatic interval operation (interval pause<br \/>adjustable from 0 &#8211; 99 minutes)<br \/>&#8211; External control<br \/>&#8211; Quantity-dependent via contact water meter<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ef0100d e-con-full e-flex e-con e-child\" data-id=\"ef0100d\" data-element_type=\"container\" data-settings=\"{&quot;_ha_eqh_enable&quot;:false}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2863149b elementor-widget elementor-widget-text-editor\" data-id=\"2863149b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>\u2022 Two independent limit values with hysteresis<br \/>(1, 2 or 3 bad analyses) and adjustable switching<br \/>functions<br \/>\u2022 Monitoring of two measuring points<br \/>(switchover by external solenoid valves)<br \/>\u2022 Internal error documentation<br \/>\u2022 Programmable service address<br \/>\u2022 Programmable maintenance interval<br \/>for maintenance request<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Testomat 2000\u00ae CLT Self Clean The Testomat 2000\u00ae CLT Self Clean process photometerwith additional cleaning function for the measuringchamber is an online analyzer for monitoring the contentof total chlorine (CLT) in the range of 0-2.5 mg\/l (ppm);switchable to free chlorine in the same measuring range. Performance Profile \u2022 Analysis by automatic addition of 3 reagents\u2022 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":28,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-757","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/heyl.choyou-tools.fr\/es_mx\/wp-json\/wp\/v2\/pages\/757","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/heyl.choyou-tools.fr\/es_mx\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/heyl.choyou-tools.fr\/es_mx\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/heyl.choyou-tools.fr\/es_mx\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/heyl.choyou-tools.fr\/es_mx\/wp-json\/wp\/v2\/comments?post=757"}],"version-history":[{"count":4,"href":"https:\/\/heyl.choyou-tools.fr\/es_mx\/wp-json\/wp\/v2\/pages\/757\/revisions"}],"predecessor-version":[{"id":761,"href":"https:\/\/heyl.choyou-tools.fr\/es_mx\/wp-json\/wp\/v2\/pages\/757\/revisions\/761"}],"up":[{"embeddable":true,"href":"https:\/\/heyl.choyou-tools.fr\/es_mx\/wp-json\/wp\/v2\/pages\/28"}],"wp:attachment":[{"href":"https:\/\/heyl.choyou-tools.fr\/es_mx\/wp-json\/wp\/v2\/media?parent=757"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}